Kleenmaid CH24 User Manual
Page 6
![background image](https://www.manualsdir.com/files/792750/content/doc006.png)
• 6 •
INJECTOR REPLACEMENT:
This appliance is suitable for use with Natural Gas or
LPG. (Check the “gas type” sticker attached to the
appliance.) The nominal gas consumption and injector size
details are provided in Table 1 on page 3.
To replace injectors
1. Remove the knobs and ignition push button
2. Unscrew the “A” screw in Figure 6
3. Remove the control panel “B” in Figure 6
4. With a wrench “C” replace the injectors “J” with
those suitable for the gas to be used (see Figure 7).
A
B
Figure 7
Figure 6
C
J
J
MINIMUM BURNER SETTING
ADJUSTMENT:
To regulate the flame follow the instructions below:
• Light the burner
• Set the cock valve to minimum
On gas valves provided with adjustment screw in
the centre of the shaft (fig. 8a):
• Using a screwdriver with max. diameter 3 mm, turn the
screw inside the tap until the correct setting is
obtained.
On gas valves provided with adjustment screw on
the valve body (fig. 8b):
• Turn the screw “A” to the correct setting with a
screwdriver.
Figure 8b
Figure 8a
A