Installation – Kleenmaid CH24 User Manual
Page 3
![background image](https://www.manualsdir.com/files/792750/content/doc003.png)
• 3 •
CAUTION:
✓ This appliance must be installed in accordance with
these installation instructions and the requirements of
the local gas authority or the appropriate installation
code issued by the A.L.P.G.A. and A.G.A. (Refer to
AG601 Code), or the Building Authority requirements.
✓ This appliance shall only be serviced by authorized
personnel.
WARNING:
✓ This appliance is to be installed only by an authorised
person.
✓ This appliance must be used only for the task it has
explicitly been designed for, that is for cooking
foodstuffs. Any other form of usage is to be
considered as inappropriate and therefore dangerous.
✓ Do NOT place combustible materials or products on
this appliance at any time.
✓ Do NOT spray aerosols in the vicinity of this
appliance while it is in use.
Natural Gas
LPG
Test Point
1.0
2.75
Pressure (kPa)
Burner
Injector Orifice
Gas Consumption
Injector Orifice
Gas Consumption
[mm]
[MJ/h]
[mm]
[MJ/h]
Simmer
0.70
2.4
0.47
2.9
Semi-rapid no.1
0.90
4.0
0.60
4.7
Semi-rapid no.2
1.15
6.5
0.76
7.5
Rapid
1.35
9.3
0.83
9.0
Wok burner
1.45
11.0
0.90
10.4
Fish warmer
1.45
11.0
0.90
10.4
(Note: Gas type sticker and data plate are attached to the underside of the base of the appliance.)
NOMINAL GAS CONSUMPTION AND INJECTOR SIZES (Table 1):
CLEARANCES:
Installation clearances and protection of combustible
surfaces shall comply with section 5.12 of AG 601 - 1995.
Figure 1
650 mm
450 mm
INSTALLATION