beautypg.com

Troubleshooting – Kemppi MinarcTig 250MLP User Manual

Page 19

background image

EN

19

Shielding gas hose (4.5 m)

W001077

Carrying straps

9592162

Remote control units

R 10

6185409

R11F

6185407

Mains cable (MinarcTig 250)

W002982

7.

trOuBleshOOting

Problem

Cause

The main switch indicator will
not light up

No electricity connected to the machine

• Check the mains supply fuses.
• Check the mains cable and plug.

Poor welding result

Several factors affect the welding quality.

• Check that the earthing clamp is properly attached, the

point of attachment is clean and that the cable and its
connectors are intact.

• Check that the shielding gas flows out of the torch tip.
• The electric network voltage is irregular, too low or too

high.

Overheating indicator lit

The device has overheated.

• Ensure that cooling air has unrestricted flow.
• The machine’s duty cycle has been exceeded. Wait for

indicator to turn off.

• Too low or high supply voltage.

If the machine’s malfunction is not eliminated with these measures, contact

KEMPPI service.