14

setting parameters

Select the welding parameters with the arrow keys (3) and adjust the

parameter values with the control knob (8). When setting the parameters,

the display (2) will show the parameter being adjusted as well as the

numeric value that will be set for it. After three seconds, the display returns

to normal state and shows the welding current value.

2.6.4 additional features for mlp models

5.

8.

minilog

With the Minilog feature, you can switch between two current levels by

pressing the switch briefly. The levels are the welding current and the

Minilog current.
To use the Minilog feature, press the button (5) so that the MINILOG

indicator is lit. Use the arrow buttons to move the selector to Minilog current

and then set the desired Minilog current level with the control knob (8).
The shielding gas starts to flow when the torch switch is pressed. When you

release the switch, the current starts to rise (if an upslope time is established)

to the set welding current level.
Press the torch swich shortly (<1 sec) you can then easily switch up and

down between the two levels: welding current and Minilog current.
When you press the switch for 1 second and then release it, the current

starts to decrease. After a predetermined downslope time, the arc is

disconnected.

14