beautypg.com

Error codes – Kemppi MinarcTig 250MLP User Manual

Page 16

background image

EN

16

t

-9…0

0

Electrode ignition pulse
(-9 = No pulse / 0 = Max pulse)

U

1/0

0

Disable automatic remote control recognition.
0 = Enable automatic recognition, 1 = Disable
automatic recognition.

*) Happens when exiting SETUP mode and value is 1.

4.

errOr CODes

The machine always checks its operation automatically during start-up and

reports any failures detected. If failures are detected during start-up, they

are shown as error codes on the control panel display.

e 2: power source undervoltage

The device has stopped because it has detected a mains undervoltage that

disturbs welding. Check the quality of the supply network.

e 3: power source overvoltage

The machine has stopped the welding because it has detected momentary

voltage spikes or continuous overvoltage dangerous to the machine in the

electric network. Check the quality of the supply network.

e 4: power source overheating

The power source has overheated. The cause may be one of the following:

• The power source has been used for a long time at maximum power.

• The circulation of cooling air to the power source is blocked.

• The cooling system has experienced a failure.

Remove any obstacle to air circulation, and wait until the power source fan

has cooled down the machine.

Other error codes:

The machine can show codes not listed here. In the event of an unlisted

code appearing, contact an authorised Kemppi service agent and report the

error code shown.