EN
synergetic mig welding parameters and their values
Name of
parameter
Name
displayed
Parameter values Factory setting
Description
Creep Start Level
Cre
10 ... 170 %
50 %
Percentage of wire feed speed, 10% refers
to slow start, 170% to accelerated start
Hot Start Level
Hot
-50 ... 75 %
30 %
Percent of welding power: -50% refers to
cold start and +75% to hot start
Crater Fill Level
CrL
10 ... 90 %
30 %
The crater fill level, 10% is the lowest
power and 90% the greatest one, relative to
welding power (preset value).
Post Current Time PoC
-9 ... +9
0
Post-welding current time
Synergic MIG Unit Unl
m/min, mm, A
m/min
In synergic welding, the parameter shown
in the left-hand side display (wire feed
speed/plate thickness/average current).
parameters common to all mig processes and their values
Name of
parameter
Name
displayed
Parameter values Factory setting
Description
Cable
Compensation
CAL
-5.0 ... 9.0 V/100 A
1.0 V/100 A
Cable compensation (MIG) for voltage
losses.
Code Entry
Cod
---, Ent
---
Entry of additional features, see page 14.
Restore Factory
Settings
FAC
OFF, PAn, All
OFF
Restores factory settings if you select ON
and exit the menu.
Scaling
SCA
0 ... 5000
0
A coefficient with which the values in the
welding machine are scaled to the scale
used by the robot.
Checking the parameters in the memOrY On state
You can check parameter values in the MEMORY ON state by pressing the button of the
parameter you want. The parameter value will be shown in the display. You cannot modify
parameter values in the MEMORY ON state.
2.3
Wire FeeDer
Wire guide adapter
The welding wire is taken to the wire feeder through a metallic wire guide adapter. Push the
wire guide to the end of the adapter and screw in with the top fixing locks. Attach a spring at
the end of the adapter to serve as the bend support for the wire guide and to prevent the wire
from bending too heavily. Fix the support spring with the bottom fixing locks.
threading the wire and adjusting tightness
1.
2.
1
KempA
rc
SY
N
300,
400,
500
/
©
Kemppi
O
y
/ 0808
FI
SV
NO
DA
EN
DE
NL
FR
ES
PL
RU