2.2.9 Optional additional mig features
In addition to the additional MIG features included in the standard delivery, it is also possible
to acquire optional features that further expand the operating features of the machine.
To use the optional features, enter a machine-specific activation code in the machine's control
panel as shown below. To purchase an activation code, contact a Kemppi representative.
Activating optional additional features
1. Press and hold down the SETUP button P8 for at least 5 seconds. The SETUP settings menu
appears on the display.
2. Select the Cod alternative with the left-hand side control knob in the control panel and
then select the value Ent using the right-hand side control knob.
3. Briefly press the SAVE button.
4. When the display on the left-hand side reads 1, enter the first value of the activation code
using the right-hand side control knob. The value you have entered is shown in the right-
hand side display.
5. Select the entry of the next value using the left-hand side control knob.
6. Enter the value corresponding to the value shown in the left-hand side display using the
right-hand side control knob.
7. Repeat steps 5 and 6 until you have entered all values of the activation code.
8. Finally, press the SAVE button briefly.
The control panel will read Suc cEs to indicate that the activation code has been entered
correctly and the additional feature is available. You can exit the code entry mode at any time
by briefly pressing ESC.
If the code entry failed, the control panel display will show an error code. For more
information on error codes, see "Troubleshooting".
The operating instructions for optional additional features can be found in the documentation
supplied with the additional feature.
2.2.10 memory features (memOrY button)
Use the control panel memory features to store welding parameters you use into the
machine's memory for easy use later without the need to readjust all parameters. The control
panel has 90 memory positions, numbered 0...89.
You can store the welding parameters you use, i.e., the wire feed speed and the welding
voltage. You can also store additional feature settings, such as creep start or crater fill settings.
storing welding parameters in memory
1. Press the MEMORY button twice. If a memory channel is free, the SET indicator starts
flashing. In other cases the indicator will be turned on constantly.
(If the memory is empty, one push of the button is enough.)
2. Select the memory channel you want using the CH button.
3. Specify the welding settings you want and store the selections by pressing SAVE.
4. Press the MEMORY button twice. The ON indicator light will turn on and the welding
parameters you selected are activated.
5. Start welding.
If you want to change the welding parameters stored in a welding channel, go to the SET
mode by pressing the MEMORY button. Now select the parameters you want and store them
by pressing SAVE.
You can also store the welding parameters with the SET button when the memory feature is in
the OFF state, i.e., when the MEMORY indicators are not on.
To clear the data in a memory channel, press the MEMORY and CH buttons simultaneously
when the control panel is in the SET mode (the SET indicator is on).
using stored welding parameters
1. Press the MEMORY button to turn on the ON indicator.
2. Select the memory channel you want from the robot.