2.1.4 Connecting the cables
+
+
G
E
F
B
A
B
D
C
Wire feeder
control
Analog
SYN 300/400/500
DT 400
Robot
KempArc
Cool10
A air hose
B shield gas hose
C air blow
D intermediate cable
E earthing cable
F cooling liquid hoses
G robot controller
Welding and earthing cables
The welding and earthing cables are rubber-insulated copper cables. The recommended
cross-sections of the cables for different power source models are as follows:
Model
Welding cable
SYN 300
50 ... 70 mm²
SYN 400
70 ... 90 mm²
SYN 500
70 ... 90 mm²
The table below shows the typical load capacities of the cables when the ambient
temperature is 25 ºC and the lead temperature is 85 ºC.
Welding cable
Duty cycle (ED)
Voltage loss / 10 m
100 %
60 %
30 %
50 mm²
285 A
370 A
520 A
0.35 V / 100 A
70 mm²
355 A
460 A
650 A
0.25 V / 100 A
95 mm²
430 A
560 A
790 A
0.18 V / 100 A
NOTE!
Do not overload the welding cables, as an overload may cause voltage loss and
overheating.