Technical data – Kemppi Evo 300 User Manual
Page 19

17
© Kemppi Oy / 1515
EN
5.
teChniCal data
Connection voltage
3 ~, 50/60 Hz
220 V -10% ... 440 V +10 %
Rated power at max. current
10.8 kVA
Supply current
30 % ED I
1max
220 – 230 V: 29 A
30 % ED I
1max
380 – 440 V: 17 A
30 % ED I
1eff
220 – 230 V: 16 A
30 % ED I
1eff
380 – 440 V: 9 A
Output 40 °C
30 % ED
300 A / 29.0 V
40 % ED
250 A / 26.5 V
60 % ED
210 A / 24.5 V
100 % ED
170 A / 22.5 V
Connection cable
H07RN-F
4G1.5 (5 m)
Fuse (delayed)
220 – 230 V
16 A
380 – 440 V
10 A
Open circuit voltage
220 V AC
42 V DC
440 V AC
86 V DC
Power factor at max. current
220 – 230 V
0.93
380 – 440 V
0.94
Efficiency at max. current
220 – 230 V
83 %
380 – 440 V
84 %
Welding voltage range
11 – 32 V
Wire spool (max. ø)
200 mm
Wire feed mechanism
2-roll feed
Wire feed speed
0 – 18 m/min
Filler wires
Fe solid, Fe cored,
Ss
0.8 – 1.2 mm
Al
1.0 – 1.2 mm
External dimensions
L x W x H
457 x 226 x 339 mm
Weight
15.4 kg
EMC class
A
Minimum short circuit power Ssc of supply network*
1.9 MVA
Degree of protection
IP23S
Operating temperature range
-20 °C ... +40 °C
Storage temperature range
-40 °C ... +60 °C
Standards: IEC/EN 60974-1, IEC/EN 60974-5, IEC/EN 60974-10
* See paragraph 2.3.