beautypg.com

Kemppi oy / 1515, 4 adjusting the shielding gas flow, 5 reversing polarity – Kemppi Evo 300 User Manual

Page 15

background image

13

© Kemppi Oy / 1515

EN

2.6.4 adjusting the shielding gas flow

Using a rotameter as shown in the picture, you can adjust the gas flow rate to the gun by

turning the shielding gas adjustment regulation valve screw inside the FitWeld Evo 300 wire

cabinet.
By turning the screw anticlockwise you increase the gas flow to the gun nozzle. Clockwise

adjustment will reduce the gas flow rate.

MM

T32

l/min

5

10

20

15

NOTE!

The shielding gas flow rate set from the gas cylinder regulator must exceed the flow rate

measured at the welding gun. If these rates are the same, the gas indication light will shine on the

control panel and welding is prevented.

2.6.5 reversing polarity

Some filler wires are recommended to be welded with the gun in the negative pole, so the

polarity should be reversed. Check the recommended polarity from the filler wire package.

to reverse polarity:

1.

Disconnect the machine from the mains.

2.

Pull away the rubber covers to expose the terminal pole connections and allow access to

the Allen screws.

3.

Using the Allen key attached to the wire cabinet wall, unscrew the pole connection bolts.

Note the correct order of washers.

4.

Interchange the cables.

5.

Install the washers in the correct order and tighten the bolts firmly.

6.

Replace the rubber covers correctly.

NOTE!

The rubber cover must always protect the poles.