EN

2.7 troubleshooting

Problem

Cause

The machine stops working and the
shielding gas indicator is lit.

The maximum flow rate at the gas cylinder is set to a lower value than the flow rate
you are trying to set with the FitWeld Evo 300 flow adjustment screw.
• At the gas cylinder’s flow regulator, set the flow rate much higher than what you

are using in welding. The final adjustment of the gas flow rate is accomplished
with the adjustment screw located inside the FitWeld’s wire cabin.

Poor welding result

Several factors affect the welding quality.
• Check that the earth return clamp is properly attached, the point of contact is clean

and that the cable and its connectors are intact.

• Check the voltage and wire speed settings on the control panel are correct for the

given wire size and type.

• Check that the shielding gas flow rate at the gun nozzle is correct.
• Check that the shielding gas is suitable for the filler wire used.
• Check that the wire feed is constant, and adjust if necessary.
• Check that the mains voltage is not irregular, too low or too high.

Overheating indicator lit

The device has overheated.
• Ensure that cooling air has unrestricted flow.
• The machine’s duty cycle has been exceeded. Wait for indicator to turn off.
• Too low or high supply voltage.

The wire does not move or wire feed
entangles

Feed rolls, wire liner or contact tips may be defective
• Check that feed rolls are not too tight or too loose.
• Check that the feed roll groove is not too worn or incorrect size for the filler wire

used.

• Check that the wire liner is the correct size and is not blocked or worn out. Replace

if necessary.

• Check that the contact tip is suitable for the wire used and and is not worn out or

blocked.

Main switch indicator does not switch
on

The machine has no mains voltage
• Check the mains fuses
• Check the mains cable and the wall plug

If the machine’s malfunction can not be corrected with these measures, contact KEMPPI

maintenance service.