Cable Compensation

CAL

-5.0 ... 9.0
V/100 A

(1.0 V/100 A)

Cable compensation (MIG)
for voltage drop

NOTE!

In crater fill, the initial value of the welding power must be greater than the final value,

and therefore the adjustment ranges for the initial and final values are restricted automatically, if

necessary.

Welding Level

Crater Fill Start Level

Crater Fill Time

Crater Fill End Level

WiseRoot

Name of parameter

Name on

display

Parameter

values

Factory setting

Description

Start Time

FSt

-9 ... +9

(0)

Start time duration in WiseRoot process
(maximum is 3 seconds)

Start Voltage Level

FuL

-30 ... +30

(0)

Voltage level of the start phase.

Common SETUP-parametres for MIG-processes (only SF53, SF55)

Name of parameter

Name on

display

Parameter

values

Factory setting

Description

Device Address

Add

3 or 6

(3)

Wire feeder bus address

Using features of PMT

Gun

Gun

OFF, on

(on)

on = PMT gun
OFF = other gun

Gas Guard Connected

GG

no, yES

(no)

yES = gas guard connected
no = gas guard not connected

LongSystem Mode

LSy

on, OFF

(OFF)

Choose position ‘on’ when using long
distance interconnection cable (>40 m)

Code Entry

Cod

---, Ent

(---)

Programming extra values,
see page 18

PIN Code Entry

PIn

---, Ent

(---)

PIN code selection
(requires MatchPIN activation)

Panel Locking

LoC

on, OFF

(OFF)

Panel lock on/off
(requires MatchPIN activation)

Restore Factory

Settings

FAC

OFF, PAn, All

(OFF)

Restores factory settings when ’on’ is
selected, exit SETUP mode

Each welding process has got SETUP-parameters of it’s own. For instance synergig MIG post

gas time has got no effect on normal MIG post gas time.
The value of the parameter is immediately recorded in the memory. Exit SETUP mode by

holding down the new SETUP button or by briefly pressing the ON/OFF button.

21

FastM

ig MSF 53, 55, 57 / © Kemppi O

y / 1515