3.3
SETUP FUNCTIONS (10)
The unit is equipped with a number of functions that can be selected. Parameters can be set
via the SETUP function. The SETUP function is activated by pressing the SETUP button (10)
for >1 second. The adjustable parameter is selected via the left-hand potentiometer (14), the
name of which is shown on display No. 2. The value of the parameter in question is adjusted
via the right-hand potentiometer (16), the value of which is shown on the display (8). The
parameters and their possible values are:
Normal MIG -welding SETUP -parametres
Name of parameter Name on
display
Parameter values
Factory setting Description
Pre Gas Time
PrG
0.0...9.9 s
0,0 s
Pre gas time in seconds
Post Gas Time
PoG
0.1 ... 32.0 s
Aut
Post gas time in seconds or
automatically according to welding
current (Aut)
Creep Start Level
CrE
10...170%
50 %
Percentage of wire feed speed:
10 % slowed start
100 % = no creep start function
170 % accelerated start
Start Power
StA
-9 … +9
(0)
Strength of start pulse
Post Current Time
PoC
-9 ... +9
0
Post current
Set Voltage Limit
U2L
25.0 ... 48.0 V
37.0 (300)
39.0 (400)
42.0 (500)
Maximum value for MIG voltage setting
Synergic MIG -welding SETUP -parametres
Name of parameter
Name on
display
Parameter
values
Factory setting Description
Pre Gas Time
PrG
0.0...9.9 s
(Syn)
Pre gas time in seconds or automatically
according to synergic welding program (Syn)
Post Gas Time
PoG
0.0...9.9 s
(Syn)
Post gas time in seconds or automatically
according to synergic welding program (Syn)
Creep Start Level
Cre
10 ... 170 %
(50 %)
Percentage of wire feed speed:
10 % slowed start
100 % = no creep start function
170 % accelerated start
Hot Start Level
Hot
-50 ... 75 %
(30 %)
Percentage of welding power:
-50 % cold and +75 % hot
Hot Start 2T Time
H2t
0.0 ... 9.9 s
(1.2 s)
The duration of the hot start in seconds in 2T
mode
Crater Fill Start Level
CrS
10 ... 250 %
(30 %)
The welding power at the beginning of the
crater fill stage as a percentage of the welding
power preset value
Crater Fill Time
CrT
0.0 ... 9.9 s
(2.0 s)
The duration of the crater fill stage in seconds
(only in 2T mode)
Crater Fill End Level
CrL
10 ... 250 %
(30 %)
The welding power at the end of the crater fill
stage as a percentage of the welding power
preset value
Start Power
StA
-9 ... +9
(0)
Strength of start pulse
Post Current Time
PoC
-9 ... +9
(0)
Post current
Synergic MIG Unit
Unl
mm, m/
min, A
(m/min)
In 1-MIG and WiseRoot welding, the parameter
shown in left-hand display: sheet thickness
(mm), wire feed speed (m/min) or average
current (A)
20
FastM
ig MSF 53, 55, 57 / © Kemppi O
y / 1515