beautypg.com

Kemppi MSF 53 User Manual

Page 22

background image

EN

3.3

SETUP FUNCTIONS (10)

The unit is equipped with a number of functions that can be selected. Parameters can be set

via the SETUP function. The SETUP function is activated by pressing the SETUP button (10)

for >1 second. The adjustable parameter is selected via the left-hand potentiometer (14), the

name of which is shown on display No. 2. The value of the parameter in question is adjusted

via the right-hand potentiometer (16), the value of which is shown on the display (8). The

parameters and their possible values are:

Normal MIG -welding SETUP -parametres

Name of parameter Name on

display

Parameter values

Factory setting Description

Pre Gas Time

PrG

0.0...9.9 s

0,0 s

Pre gas time in seconds

Post Gas Time

PoG

0.1 ... 32.0 s

Aut

Post gas time in seconds or
automatically according to welding
current (Aut)

Creep Start Level

CrE

10...170%

50 %

Percentage of wire feed speed:
10 % slowed start
100 % = no creep start function
170 % accelerated start

Start Power

StA

-9 … +9

(0)

Strength of start pulse

Post Current Time

PoC

-9 ... +9

0

Post current

Set Voltage Limit

U2L

25.0 ... 48.0 V

37.0 (300)
39.0 (400)
42.0 (500)

Maximum value for MIG voltage setting

Synergic MIG -welding SETUP -parametres

Name of parameter

Name on

display

Parameter

values

Factory setting Description

Pre Gas Time

PrG

0.0...9.9 s

(Syn)

Pre gas time in seconds or automatically
according to synergic welding program (Syn)

Post Gas Time

PoG

0.0...9.9 s

(Syn)

Post gas time in seconds or automatically
according to synergic welding program (Syn)

Creep Start Level

Cre

10 ... 170 %

(50 %)

Percentage of wire feed speed:
10 % slowed start
100 % = no creep start function
170 % accelerated start

Hot Start Level

Hot

-50 ... 75 %

(30 %)

Percentage of welding power:
-50 % cold and +75 % hot

Hot Start 2T Time

H2t

0.0 ... 9.9 s

(1.2 s)

The duration of the hot start in seconds in 2T
mode

Crater Fill Start Level

CrS

10 ... 250 %

(30 %)

The welding power at the beginning of the
crater fill stage as a percentage of the welding
power preset value

Crater Fill Time

CrT

0.0 ... 9.9 s

(2.0 s)

The duration of the crater fill stage in seconds
(only in 2T mode)

Crater Fill End Level

CrL

10 ... 250 %

(30 %)

The welding power at the end of the crater fill
stage as a percentage of the welding power
preset value

Start Power

StA

-9 ... +9

(0)

Strength of start pulse

Post Current Time

PoC

-9 ... +9

(0)

Post current

Synergic MIG Unit

Unl

mm, m/
min, A

(m/min)

In 1-MIG and WiseRoot welding, the parameter
shown in left-hand display: sheet thickness
(mm), wire feed speed (m/min) or average
current (A)

20

FastM

ig MSF 53, 55, 57 / © Kemppi O

y / 1515

This manual is related to the following products: