2.12 OPERATION OF COOLING UNIT, FASTCOOL 10

Operation of cooling unit is controlled in such a way that pump is started when welding is

started. After welding stop pump is rotating for approx. 5 min cooling the gun and the cooling

liquid to ambient temperature.
Read in operation instructions for the Fastcool 10 unit the trouble situations of the liquid

circulation system and protection against torch etc. damage.

2.13 HANGING

MSF 53 needs hanging frame (accessorie) for mounting, do not hang from the handle. MSF 55

and MSF 57 can be hanged from hanging kit available as an accessorie.

3.

CONTROL PANELS OPERATIONS

3.1

SF 51 AND SF 54 OPERATIONS

1.

2.

11.

9.

3.

4.

6.

5.

7.

13.

12.

8.

10.

Main switch, ON/OFF (1)

The wire feed unit remains in the OFF position when the power source is switched on, thus

preventing start-up. ’OFF’ is shown on the display.
When the ON/OFF button is pressed for more than 1 second, the unit starts up. The unit is now

ready for welding and will automatically return back to it previous position, before the power

was cut off. The wire feed unit starts up also by pressing three (short) times the switch of the

welding gun.

Basic settings and displays (11, 12, 2, 8)

The wire feed speed is set via potentiometer (11), the value of which is shown on display (2).

The welding voltage is set via potentiometer (12), the value of which is shown on display (8).

During welding, display (2) shows the actual welding current value and display (8) shows

welding voltage.
When MIG dynamics adjustment is activated via button (3), the MIG dynamics value is

adjusted through potentiometer (12) (see ’Adjustment of MIG dynamics’).
With electrode welding (MMA), the welding current value is set via the potentiometer, the

value of which is shown on display (2). Display (8) shows the idling voltage of the power

source. During welding, display (2) shows the actual welding current value and display (8)

shows the welding voltage.