beautypg.com

Kemppi Kempact Pulse 3000 User Manual

Page 15

background image

EN

When pressed simultaneously, the weld data buttons recall the wire feed speed on the display,

the welding voltage and welding current values which have been used when welding was

stopped.

3.3.5 Timer

intermittent welding
spot welding
The spot time is set immediately after pressing the switch button, on the display SPt. The

pause time is set accordingly, on the PSE display. The time is set using the Process Manager.

3.3.6 Adjustment of welding dynamics

For adjusting of MIG/MAG welding dynamics, the adjustment value dyn -9...0...9 is displayed.

The welding stability and quantity of spatter are affected by the welding dynamics control,

the 0-position is the recommended reference range. Values -9...-1 give a smoother arc and less

spatter, while values 1...9 give a rougher arc and increased stability, when using a 100% CO

shielding gas when welding steel.

3.3.7 Remote control

Gun control, wire feed speed or welding power control is changed using RMT 10. Control of

the welding voltage or the length of the welding arc can be adjusted using the potentiometer

on the panel. Panel control, adjustments using the potentiometer on the panel.

13

Kempac

t P

ulse 3000, Kempac

tC

ool 10 / © Kemppi O

y / 1136

This manual is related to the following products: