Symbologies
6-6
PowerScan
®
7000 2D
Code 39 Check Character
No Check Character
indicates that the imager reads and transmits bar code
data with or without a check character.
When Check Character is set to
Validate, but Don’t Transmit
, the unit only
reads Code 39 bar codes printed with a check character, but will not
transmit the check character with the scanned data.
When Check Character is set to
Validate and Transmit
, the imager only
reads Code 39 bar codes printed with a check character, and will trans-
mit this character at the end of the scanned data. Default = No Check
Character.
Code 39 Message Length
Scan the bar codes below to change the message length. Refer to
Mes-
sage Length Description on page 6-2
for additional information. Mini-
mum and Maximum lengths = 0-48. Minimum Default = 0, Maximum
Default = 48.
Validate, but Don’t Transmit
* No Check Character
Validate and Transmit
Minimum Message Length
Maximum Message Length