Press abutment solutions, Permanent cementation ti base / meso-structures – Ivoclar Vivadent IPS e.max Abutment Solutions Cem Kit v.3 User Manual
Page 8

8
Careful preparation of the bonding surface is a prerequisite for an optimum adhesive cementation of the Ti base and
the pressed object. The following paragraphs outline the required procedures. The procedure is the same for hybrid
abutments and hybrid abutment crowns.
IPS e.max Press Abutment Solutions (LS
2
)
Abutment, abutment crown
(LS
2
)
Ti base
Blasting
–
The bonding area with Al
2
O
3
at low pressure
Etching
The bonding area with
IPS
®
Ceramic Etching Gel for 20 s
–
Conditioning
The bonding area with Monobond Plus for 60 s
Adhesive cementation
Multilink Implant MO 0
Covering the cementation joint
Glycerine gel, e.g. Liquid Strip
Curing
7-minute curing
(optional in a light-curing device)
Polishing the cementation joint
Customary polishers for ceramic/resin materials
Abutments made of zirconium oxide (ZrO
2
)
Meso-structure
(ZrO
2
)
Ti base
Blasting
The bonding area with Al
2
O
3
at low pressure
The bonding area with Al
2
O
3
at low pressure
Conditioning
The bonding area with Monobond Plus for 60 s
Adhesive cementation
Multilink Implant MO 0
Covering the cementation joint
Glycerine gel, e.g. Liquid Strip
Curing
7-minute curing
(optional in a light-curing device)
Polishing the cementation joint
Customary polishers for ceramic/resin materials
Pre-treatment of the Ti base
To prepare the Ti base for cementation with the meso-structure, please observe the following procedure:
– Observe processing instructions of the manufacturer of the Ti base.
– Clean the Ti base in an ultrasonic cleaner and blow dry or use a steam cleaner.
– Screw Ti base onto a model analog.
Press
Abutment Solutions
Permanent Cementation Ti base / Meso-structures