beautypg.com

Product description, 1 components, 2 hazardous areas and safety equipment – Ivoclar Vivadent IvoBase Injector v.2 User Manual

Page 10: 3 functional description

background image

10

3. Product Description

3.1 Components

The IvoBase Injector comprises the following components:
– Basic injector with polymerization chamber and operating panel
– Flask
– Waste water container
– Power cord

3.2 Hazardous areas and safety equipment

Description of the hazardous areas of the injector:

Hazardous area

Type of risk

Polymerization chamber

Burn hazard

Polymerization chamber

Risk of crushing

Electrical components

Risk of electrical shock

Description of the safety equipment of the injector:

Safety equipment

Protective effect

Protective conductor

Protection from electrical shock

Electrical fuses

Protection from electrical shock

Housing and end caps

Protection from electrical
shock, burning and crushing

Red warning light (5)

Warns against hot components
in the polymerization chamber

3.3 Functional description

The IvoBase Injector has been developed for the IvoBase System and
allows an automated and controlled injection process. The injector
may be used for both self-curing and heat-curing polymers. The
integrated heater permits the flask to be heated up to 120 °C
(248 °F). With the controlled and automated injection, high-quality
products with outstanding physical properties can be fabricated.

The injection process taking place in the IvoBase Injector can be
basically divided into four stages (see image):

1. Dough stage: During this stage, the material changes to an

injectable consistency.

2. Injection phase: During this stage, the material is injected into the

flask by means of a forward movement of the injection head.

3. Polymerization stage: The controlled heat supply initiates the

polymerization with shrinkage compensation.

4. Cooling stage: During the cooling stage, the system normalizes

the temperature and the tension.

1. Dough

stage

2. Injection stage

3. Polymerization stage

4. Cooling

stage

(optional)

Temp

er

at

ur

e

In

je

cti

on

fo

rce