beautypg.com

Installation and initial start-up – Ivoclar Vivadent EP 5010 User Manual

Page 18

background image

18

Step 5:
Close the covering hood.
Once all cables are properly connected to the furnace base, close the
covering hood over the connections.

Step 7:
Establish additional connections.
Connecting the power
Please make sure that the voltage indicated on the rating plate
complies with the local power supply. Subsequently, connect the
power cord with the power socket of the furnace.

The furnace must only be operated with the supplied

power cord!

Connecting the vacuum pump
Connect the vacuum pump plug with the vacuum pump socket.
We recommend using only a vacuum pump from Ivoclar Vivadent
(VP4 / VP5), since these pumps are especially coordinated with the
press furnace. If other pumps are used, please observe and do not
exceed the maximum power consumption.

Do not shorten the vacuum hose! The minimum length of

the vacuum hose is 1.6 m.

Step 6:
Mount the connection cover.
Mount the connection cover and secure it with the fastening screw.
Make sure that the lateral catch springs snap into place when
mounting the connection cover.

The furnace must only be operated with the covering

hood closed and the connection cover mounted!

4. Installation and Initial Start-Up

26

25

29

30

32

33