Ivoclar Vivadent IPS Eris for E2 User Manual
Page 21

21
Processing procedure Empress 2 /
Eris for E2 layering technique
IPS
IPS
Die stone type IV
Fabricating the model
Fabricate a type IV die stone model with detachable
segments according to the impression.
Applying the spacer
It is advisable to apply a sealer to harden the surface and to
protect the die.
The application of a sealer must not cause any changes in
the dimensions of the die.
a) For single crowns, apply two layer of spacer up to
maximum 1 mm from the preparation margin (layer
thickness of spacer: 9–11 µm).
b)Bridge restorations also require two layers of spacer. Apply
an additional layer of spacer to the intercoronal surfaces of
the abutments (the area facing the pontic). This measure
helps prevent undesired friction.
The spacer is applied to maximum 1 mm from the preparation margin.
Schematic of the space layer.
Crown
- 14K (2 pages)
- 24K (2 pages)
- BioUniversal KFG (2 pages)
- Capricorn 15 (2 pages)
- Callisto 86 (2 pages)
- Harmony KF (2 pages)
- Callisto 86 (2 pages)
- BioUniversal KFG (2 pages)
- BioUniversal KFG (2 pages)
- BioUniversal E (2 pages)
- BioUniversal PdF (2 pages)
- Brite Gold (2 pages)
- Capricorn 15 (2 pages)
- Callisto Implant 33 (2 pages)
- Capricorn (2 pages)
- Colado CC (2 pages)
- Callisto 84 (2 pages)
- Callisto CP+ (2 pages)
- Callisto CPG (2 pages)
- Callisto Implant 60 (2 pages)
- CosmoPost (24 pages)
- Colado NC (2 pages)
- Elektra (2 pages)
- Evolution Lite (2 pages)
- ESPRIT (1 page)
- Elektra 10 (2 pages)
- IPS d.SIGN Ultra (2 pages)
- EP 5000 (1 page)
- Harmony 2 (2 pages)
- EP 600 (36 pages)
- Harmony Hard (2 pages)
- Harmony Medium (2 pages)
- Harmony Soft (2 pages)
- Heliobond (36 pages)
- Harmony 3 (2 pages)
- Harmony C&B 55 (2 pages)
- EP 600 Combi (40 pages)
- Harmony PF (2 pages)
- Harmony X-Hard (2 pages)
- IPS AcrylCAD (2 pages)
- IPS d.SIGN 30 (2 pages)
- IPS Classic (24 pages)
- IPS d.SIGN 59 (2 pages)
- IPS d.SIGN 84 (2 pages)
- IPS d.SIGN 96 (2 pages)