Product specification – Ivoclar Vivadent EP 600 Combi User Manual
Page 33

33
9.2 Technical data
Power supply:
200–240 Volt, 50–60 Hz
110–120 Volt, 50–60 Hz
Installation category II
Max. power consumption:
12 A at 110–120 VAC
8,5 A at 200–240 VAC
Vacuum quality:
100% 40–120 mbar
Acceptable data for pumps of other manufacturers:
Max. power consumption: 2,1 A
Final vacuum: < 50 mbar
Use only tested pumps!
Electrical fuses:
200–240V: T 6,3 A (heating circuit) T 1 A (controls)
T3,15 A (vacuum pump)
110–120V: T 12 A (heating circuit) T 2 A (controls)
T5 A (vacuum pump)
Fuse dimensions:
200–240V = diameter 5 x 20 mm
110–120V = diameter 6,3 x 32 mm
Dimensions:
w x d x h: 445 x 520 x 650 mm
Usable size of the press chamber:
diameter 50 mm, height 85 mm
Usable size of the firing chamber:
diameter 80 mm, height 50 mm
Max. press and firing temperature:
1200 °C
Weights:
Furnace head: 7,6 kg
Furnace base: 17,0 kg
Tray: 0,4 kg
Press furnace, complete: 25,0 kg
Extra muffle: 0,3 kg
Safety information:
IEC 1010-1, EN 61010-2-020, Part 1
ULC and cUL standards
Radio protection, electromagnetic compatibility:
EMC tested
This chapter contains all the
relevant product specifications.
9.1 Delivery form
EP600 Combi
– EP600 Combi incl. software
– Sagger tray
– Automatic Temperature
Checking Set 1 (complete)
– Investment ring cooling grid
– Power cord
– Vacuum hose
– Firing tray
– ECO-5000 card reader incl.
power pack
– 3 program memory cards
– Operating Instructions
– Firing plate (slit)
Accessories
– Refill package ATK1 "Melting
Samples"
– Refill package ATK 1 " Cera-
mic Base Block"
– VP3 Vacuum Pump
– Program memory cards
– Download cable
Colours
Standard colour:
Traffic white (RAL 9016)
Special colours:
– Salmon (RAL 3014)
– Aquamarine (RAL 5014)
– Turquoise (RAL 6027)
9. Product Specification