beautypg.com

Installation – IHSE USA 461 Series DVXi/ET KVM Extender User Manual

Page 19

background image

INSTALLATION

19

Fiber Cable: Two strands of fiber are required for singlehead devices, four strands for
Dualhead devices.

Please note, that the allowed distance will depend on device type AND on
used fiber type.

Recommended cables:
K462-xx: Multimode type 50/125µ

allowed distance app. 400m (1,300ft)

K462-xx: Multimode type 62.5/125µ

allowed distance app. 200m (650ft)

K463-xx: Singlemode type 9/125µ

allowed distance app. 10km (32,750ft)

A point to point connection is required. Having one or more patch panels
in the line is possible and allowed. Not allowed is a connection from the
Fiber link interface (LC) to any other products, especially

telecommunications or network equipment.

Our experiences show, that Singlemode devices regularly work well on
Multimode Fibers where vice versa it will never do. In addition we found,
that Singlemode devices on Multimode fibers may extend the allowed

distance on Multimode fibers to twice the regular length. Anyway this
cannot be guaranteed and must be evaluated by the end-user at his own
expense.

Power Supply: Connect the supplied 5V/DC power supplies to the Plug terminal on the
rear of both local and remote units.

This manual is related to the following products: