User codes, System test – DMP Electronics XR6 User Manual
Page 18
14
User Codes
User Code Level: Master only.
Function: Allows you to add or delete a user from the system or
change their security code or authority level.
There are three characteristics associated with each user code that
define its capabilities within the system.
10
3812
Master
User Number - Your system supports twelve users. Each user is
numbered from 1 to 12. This number identifies them to the system and
is transmitted to the central station (if your system is monitored) when
they arm or disarm the system.
Security Code - Users also have a 4-digit security code that they
enter into the keypad when arming or disarming. This security code
is kept secret from other users and is not transmitted to the central
station when they arm or disarm.
A user enters
only their security code when operating the system.
Authority Level - The user is also assigned a level of authority
(Master or Standard) by the person administrating the system that
determines the functions they can access.
The table to the right lists system functions users are allowed to
access based on the authority level assigned to their codes at the
time they’re added to the system.
System Test
User Code Level: Master or Standard.
Function: System Test is used to test the battery, alarm bell or siren,
and communication to a central station. The System Test function
begins automatically as soon as you select it.
Using the System Test Function
1. Access the User Menu.
2. Press the COMMAND key until SYSTEM TEST? displays.
3. Press any one of the SELECT keys. The system test begins
automatically and the keypad displays:
1) BELL SOUNDING during a two second bell test, then:
2) BATTERY - OKAY or BATTERY - TRBL to indicate the
condition of the battery, then:
* 3) TRANSMIT TEST and ATTEMPT NO : 1 during the
transmit test, then:
4) TRANSMIT OKAY or TRANSMIT FAILED to show the
results of the transmit test, then:
5) TEST END to indicate the System Test is complete.
6) You can end the transmit test by pressing the ARROW key.
* The transmit test does not operate on local systems.
Testing your system's burglary protection: The System Test
function should be part of your weekly testing and should be followed
by placing the interior and perimeter burglary devices in Zone Monitor
mode. This allows you to open and then close each protected door
and window while listening for the keypad to beep confirming its
operation. See Zone Monitor.
User Menu
User number
Security Code
Authority level