Home/away system disarming – DMP Electronics XR6 User Manual
Page 14
10
Home/Away System Disarming
Disarming: While the system is armed, you can only enter the
premises through an entry/exit delay door without causing an alarm.
After opening the door, the Security Command keypad sounds a
prewarn tone to remind you to disarm the system. You must disarm
the system before the prewarn tone expires or an alarm on the door
zone will occur.
During the prewarn tone, the keypad displays ENTER CODE:. Enter
your code to disarm the system.
Alarm Display: After disarming, the keypad displays any zones that
tripped or any transmission problems that occurred during the armed
period. All burglary zones are then disarmed and any bypassed
zones are automatically reset.
Disarmed Message: The keypad displays ALL SYSTEM OFF after
the system disarms.
Central Station Report: A report of the system disarming can be
transmitted to the central station. This is optional and can be
programmed for you at any time.
Easy Exit™ Feature
While the system is armed, you can also just press the COMMAND
and then the 9 key to restart the exit delays to allow you to exit the
premises without disarming the system. After the exit delay time
expires, the system rearms automatically. This feature allows you to
get the paper, let your pet out, or leave for work without having to
disarm and then rearm the system.
Arming and Disarming
Disarming a Home/Away System
1. During the entry delay, the keypad displays ENTER CODE:.
Enter your 4 digit security code.
2. The keypad then displays any alarms or communication problems
that occurred during the armed period.
3. The keypad next displays ALL SYSTEM OFF to confirm the
system is disarmed.
Disarming During an Alarm
1. While the alarm bell or siren is sounding, enter your 4 digit
security code. The keypad displays DISARM SILENCE.
2. Press the SELECT key under DISARM to disarm the system and
silence the alarm.
The keypad next displays ALL SYSTEM OFF to confirm the
system is disarmed.
3. Press the SELECT key under SILENCE to stop the bell or siren
but NOT disarm the system.
4. If your system is programmed to send an Abort (alarm cancel)
report to the central station, the keypad displays ALARM
CANCELLED.
If you do not press any SELECT key while DISARM SILENCE is
displayed, the system automatically selects DISARM and disarms
the system.