13
User Menu
Zone Monitor
User Code Level: Master and Standard.
Function: Allows the system to monitor selected disarmed zones
(doors, windows, or motion detectors) and sound a tone at the keypad
as well as display their name on the keypad display as they're faulted.
This is an ideal feature for monitoring door zones to tell when
someone comes in or goes out.
You can place any combination of disarmed zones in Zone Monitor
but only the most recent zone faulted is displayed. The displayed
zone name clears automatically after a short time or when the zone
is armed.
Zone Monitor does not function while the system is armed but a zone
placed into it will still be there when the system is disarmed.
Using Zone Monitor as part of your weekly system test: After
using the System Test function (see page 14), place all perimeter and
interior zones in Zone Monitor. Starting at the front door, go around
and open and then close each door and window. You should hear the
keypad beep each time. The keypad will also display the name of
each zone as its device is opened.
Once all protected doors and windows have been tested, walk in front
of each motion detector. The keypad should beep to confirm their
operation. If at any time during your weekly testing a device does not
cause the keypad to beep, call the service department for assistance.
Using the Zone Monitor Function
1. Access the User Menu.
2. Press the COMMAND key until ZONE MONITOR? displays.
3. Press any one of the SELECT keys.
The keypad displays PERIM ALL NBR .
4. Select PERIM to place all disarmed perimeter zones into Zone
Monitor.
4a. The keypad displays PERIM? ADD RMV.
4b. Select ADD to add all perimeter zones to Zone Monitor.
4c. Select RMV to remove all perimeter zones.
5. Select ALL to place all disarmed perimeter and interior zones
into Zone Monitor.
5a. The keypad displays ALL? ADD RMV.
5b. Select ADD to add all disarmed zones to Zone Monitor.
5c. Select RMV to remove all disarmed zones.
6. Select NBR to enter a specific zone number for zone monitor.
7. If NBR is selected, the keypad displays ZONE : - ADD RMV.
7a. Enter any zone number and select ADD to add this zone.
7b. Enter any zone number and select RMV to remove this
zone.
8. The zone number automatically disappears and a new zone
number can then be entered in step 7a.