beautypg.com

Focal position locations -11, Focal position locations, Definitions – Hypertherm LH2100 User Manual

Page 38

background image

0

OPERATION

LH2125/LH2100 Laser Head Instruction Manual

4-11

Focal position locations

Effective focal lengths listed in the table are for Hypertherm lenses only. The formulas in the table will help determine the
focal position for each lens and lens-bay if Hypertherm lenses are not being used.

Definitions

Lens bay location (LBL) = Location of the lens bay relative to the nozzle exit

Edge thickness (ET) =

Back focal length (BFL) = The distance from the lower edge of the lens to the focal point

Lens position (LP) = The number read off the indicator on the laser head

Effective focal

length

(Hypertherm

lenses)

Lens bay location

(LBL)

relative to nozzle

Edge

thickness

(ET)

Back focal

length

(BFL)

Lens

position

(LP)

read by

indicator

Formula

LBL-ET-BFL-LP=FP

Focal

position

(FP)

relative to

nozzle

7.5"

P/N 021006

206.7 mm

(8.14")

7.9 mm

(0.31")

185.3 mm

(7.30")

7.0 mm

(0.28")

206.7 - 7.9 - 185.3 - 7.0 = 6.5 mm

8.14 - 0.31 - 7.3 - 0.28 = 0.25 in

6.5 mm

(0.21")

10.0"

P/N 021007

270.4 mm

(10.65")

7.9 mm

(0.31")

252.5 mm

(9.94")

7.0 mm

(0.28")

270.4 - 7.9 - 252.5 - 7.0 = 3.0 mm

10.65 - 0.31 - 9.94 - 0.28 = 0.12 in

3.0 mm

(0.46")

12.5"

P/N 021008

336.5 mm

(13.25")

7.9 mm

(0.31")

314.7 mm

(12.39")

7.0 mm

(0.28")

336.5 - 7.9 - 314.7 - 7.0 = 6.9 mm

13.25 - 0.31 - 12.39 - 0.28 = 0.27 in

6.9 mm

(0.31")

Beam

BFL

Hypertherm lenses are rated for 20.7 bar (300 psi)

This manual is related to the following products: