INSTALLATION
3-10
LH2125/LH2100 Laser Head Instruction Manual
Lens installation
ቢ
Check condition of the lens seal before insertion. If there are any cuts or abrasions, replace seal. See Parts List.
ባ
Orient lens tab in upward position, seal downward. Door will not close if lens is incorrectly oriented.
ቤ
Align lens tab with cut out in lens door to allow lens door to close.
ብ
Close and latch lens door securely.
Note 1: Seal is designed to operate dry. Do not lubricate.
Note 2: Only 1 lens can be used at a time for a process. Empty lens bays must have a lens blank
installed before cutting. See Parts List for part number.
Lens tab in upward position
Seal (not shown)
ቢባ
Lens door
Lens tab
Cut-out
ቤ
ብ
12.5" lens bay
(LH2125 only)
10" lens bay
7.5" lens bay