Cleaning Glass

Clean glass with any commercial glass cleaner or

soap and water. Do not use any abrasive material

to clean glass. Do not clean glass with any cool

water if glass is still hot from the fire and smoke.

A gas line or gas log lighter may be installed for the

purpose of installing a vented or vent-free deco-

rative gas appliance incorporating an automatic

shutoff device and complying with the Standard

for Decorative Gas Appliances for Installation in

Vented Fireplaces, ANSI Z21.60 or American Gas

Association draft requirements for Gas Fired Log

Lighters for Wood Burning Fireplaces, Draft NO.

4 dated August, 1993.

If you wish to install an unvented (vent-free) gas

log set, only unvented gas log sets which have been

found to comply with the standard for unvented

room heaters, ANSI Z21.11.2 are to be installed

in this fireplace.

OUTSIDE AIR AND DAMPER
HANDLE OPERATION

The damper handle, which opens and closes the

damper blade, is located in the upper front face

of the fireplace. Pushing the handle forward and

up through the keyway slot will free damper

blade to automatically open. Pushing the handle

forward and down will lock damper blade closed

(see Figure 31).

The outside air kit lever is located at the left and

right hand sides of fireplace (see Figure 32). Lift-

ing lever up will free the outside air door to open.

Pulling lever down will lock the door.

WARNING: Risk of fire! Re-

place grate with DESA model

109496-03 GM36, 109496-02

GM42, 109496-01 GM50 grate only.

This grate has been designed to

keep the operation of your fire-

place safe and efficient.

opeRation and

Maintenance guidelines

Continued

Figure 31 - Operating Damper Handle

Damper
Weight

To Close
Damper

To Open
Damper

Damper
Weight

Open Position

Closed Position

Figure 32 - Outside Air Kit Lever

technical seRVice

You may have further questions about installation,

operation, or troubleshooting. If so, contact DESA’s

Technical Service Department at 1-866-672-6040.

When calling please have your model and serial

numbers of your heater ready.

You can also visit DESA’s technical services web

site at www.desatech.com.