optional gas line

installation

Continued

CAUTION: All gas piping

and connections must be tested

for leaks after the installation

is completed. After ensuring

that the gas valve is on, apply

soap and water solution to all

connections and joints. Bubbles

forming show a leak. Correct

all leaks at once. DO NOT USE

AN OPEN FLAME FOR LEAK

TESTING AND DO NOT OPER-

ATE ANY APPLIANCE IF A LEAK

IS DETECTED. LEAK TESTING

SHOULD BE DONE BY A QUALI-

FIED SERVICE PERSON.

WARNING: Do not oper-

ate an unvented gas log set in

this fireplace with the chimney

removed.

If you install a decorative gas appliance (vented

gas log), the decorative gas appliance must comply

with the Standard for Decorative Gas Appliance

for Installation in Solid Fuel Burning Fireplaces,

ANS Z21.60, Z21.84 or RG 2-72 and shall also be

installed in accordance with the National Fuel Gas

Code, ANSI 7223NFPA 54 latest edition.

WARNING: If the fireplace

has been used for wood burning,

the firebox and chimney must be

cleaned of soot, creosote and

ashes be a qualified chimney

cleaner. Creosote will ignite if

heavily heated.

WARNING: When using a

decorative vented gas log, the

damper must be removed or

permanently locked in the fully

open position and the glass

doors must be in the fully open

position.

Figure 18 - Gas Line Knockout

Side
Firebrick
Finished
Side

Refractory
Knockout
Plug

Outside of
Fireplace

Gas Line
Conduit

Insulation

Gas
Conduit
Cover

1/2" Dowel

Seal
Opening
with
Refractory
Cement

Outside of
Fireplace

Gas
Line
Conduit

Repack
Insulation

Incoming
1/2" Black
Iron Pipe

Side
Firebrick
Finished
Side

Provide Enough Threaded
End for Fitting Connection

Figure 19 - Gas Line Installation

Remove
Knockout