beautypg.com

Guralp Systems CMG-CD24R8 User Manual

Page 8

background image

CD24-R8

The network interfaces are implemented using Lantronix WiPort-NR

modules. To configure the network settings, please see Chapter 4 on
page 11.

The GPS receiver should be connected to only one CD24-R8. A GPS

“daisy-chain” cable is used to pass timing information to other units in
the rack.

The CD24-R8s are supplied with separate power supplies but, if a

suitable DC power source is available, a “daisy-chain” power supply
cable can be made up to run all the units from a single supply.

To view the digitisers' outputs in Scream, open the Network Control
window (

+

) and, for each unit, add a new TCP server on port

10,002.

2.1.6 Multiple CD24-R8s with an EAM-R

The CMG-EAM-R is a data acquisition device with data-concentration,

storage, processing and protocol-conversion facilities. It has been
designed for use with up to seven CD24-R8 digitisers. For further

information about the CMG-EAM-R, please see document MSH-EAM-
0005, available from GSL support (email:

[email protected]

).

8

Issue B