background image

Operator’s Guide CMG-1T Ocean Bottom
Seismometer

September, 1999, Issue C Section 9,
Page 3

Many methods can be used to restrain the movement of the levelling system
within the glass bowl. The preferred method used by us is given in the
following photographs.






































A set of attachment points are glued to the inside of the glass sphere from which

semi-flexible linkages are used to attach the bottom of the levelling platform to

the glass sphere. Six separate holes are provided for such linkages.