beautypg.com

Gullco PK-500-LG-x User Manual

Page 48

background image


44

“ELECTRODE SENSE ” (pink wire): terminate this wire to welding power source electrode

sense connection. May not be necessary / available on some makes and models
of power sources.

Used by the welding power source to measure the actual welding voltage.

“CABLE SHIELD ” (supplied from the factory covered in a light green heat shrink): Under
normal circumstances is not required to be terminated. But in the event that there is the
presence of high frequency interference or other RFI causing the PipeKAT

®

to malfunction then

it is advised to terminate this wire to the chassis / frame ground of the welding power source.

IMPORTANT:

If any of the above wires are not used for interfacing with the welding power

source then they must be properly terminated and electrically isolated to prevent electrical
shorting.