Gullco PK-500-LG-x User Manual
Page 30
![background image](https://www.manualsdir.com/files/788288/content/doc030.png)
26
Table of Oscillator Head Values
Increments
Increments
Oscillator
Head Model
Units Of
Measure
Minimum
Speed
Maximum
Speed
of
Speed
Adjustment
Range
Without
Dwells
Range
With
Dwells
of
Width
Adjustment
Units of
Travel per
Motor Step
Inches
0.5 "/min
140 "/min
0.5 "/min
0.09" - 0.18"
0.19" - 2.50"
0.01"
0.00050000
Cm
1 cm/min
355 cm/min
1 cm/min
0.23 - 0.46 cm
0.47 - 6.35 cm
0.01 cm
0.00127000
PK-500-012
(Standard
Linear)
Width of Oscillation
Note:
Linear stroke is 4” [10.2cm] on PK-500-012 with 2.5” [6.35cm] maximum oscillation width.
Oscillator Control Motor (PK-200-300) Board Dip Switch Settings
The Oscillator Control Motor Board is located inside the control box that is mounted on
the PIPE KAT
®
carriage.
Dip Switch S42:
Switch # 1
Switch # 2
Setting
Off Off Future
use
On
Off
When used on a Gullco Pipe KAT
®
Off On Future
use
On On Future
use