28
ER.44: (PWS main control communication)
During normal operation of the PIPE KAT
®
the main control communicates with the oscillator
control, if for any reason this communication becomes corrupt ER.44 will be displayed on the
control.
ER.45: (Oscillator control keypad)
The Oscillator control uses and keypad and a display located in the main control box. For any
reason if a malfunction occurs on the keypad board ER.45 will be displayed on the control.
ER.46: (Oscillator control motor board)
During normal operation of the PIPE KAT
®
the oscillator control communicates with oscillator
control motor board located on the PIPE KAT
®
carriage, if for any reason this communication
stops or becomes corrupt ER.46 will be displayed on the control.
ER.47: (Oscillator control motor board over temp)
During normal operation of the PIPE KAT
®
if the oscillator motor control board reaches 96°C
[205°F] ER.47 will be displayed on the control.
ER.49: (Oscillator control display)
During normal operation of the PIPE KAT
®
if the oscillator display encounters a malfunction
ER.49 will be displayed on the control.