Model 2450a disassembly & assembly – Groth 2000A User Manual
Page 13

13
MODEL 2450A DISASSEMBLY & ASSEMBLY
ITEM DESCRIPTION
ITEM DESCRIPTION
1 Body
17
Stem
Guide
2
Pallet – Pressure
18
Seat – Vacuum
3
Retainer Plate – Pressure
19
Hex Bolt, 3/8-16 UNC
4
Hinge Arm
20
Flat Washer, 3/8", SS
5
Hinge Pin
21
Hex Nut, 3/8-16 UNC
6
Cotter Pin
22
Lock Washer, 3/8"
7
Hex Nut, 3/8-16 UNC
23
Pallet – Vacuum
8
Lock Washer
24
Retainer Plate – Vacuum
9
Washer, 3/8", PTFE
25
Crown Nuts, 3/8- 16
10
Diaphragm – Pressure
26
Screen
11
Diaphragm – Vacuum
27
Weatherhood Post
12 Spacer
28 Water
Dam*
13 Weatherhood
29 Weight
Plate*
14
Stem – Vacuum
30
Handle*
15
Hex Nut, 1/2-13 UNC
31
Spring
16 Spring
Button
32
Hex Bolt, 3/8-16 UNC
* Not used on valves with low settings.
2450 DISASSEMBLY
1. Read “Warning” sections on pages 4 and 6. Remove the valve from the tank.
2. Remove hinge pin [5], and cotter pin [6] from the hinge arm and brackets.
3. Lift pressure/vacuum pallet [2] with attached assembly from body [1].
4. Using the handles [30] on the weight plate [29], or the edges of the pallet [2], lift vertically. Set the
cover on a short length of pipe (minimum 6” high) (Figure 13). This will elevate the retainer plate
peripheral guides above the table so they aren’t bent or damaged.
5. Remove crown nuts [25], lift weatherhood [13], bird screen [26] and set aside.
6. Record “A” dimension (Figure 14). Place a short length of pipe (minimum 6” high) beneath the
vacuum pallet [23] to prevent it from falling. Back the top nut [15] completely off the stem. Compress
the spring using the spring button [16] and grasp the stem (Figure 15). Caution: Remove the