26. Mount the parallelogram rod support to the first section and first rod and also the third
section and third rod as described on page 10.
27. Connect the remote bracket angle adjuster to the end of the last section and secure it
with the provided safety pin.
Tip: The angle adjuster has an integrated leveller. By turning it, the vertical plate on
the angle adjuster can be set to a perfect right angle. Correct setting of the angle
adjuster enhances the crane’s balance.
28. Insert the rod on the remote bracket angle adjuster into the parallelogram rod a
secure with the safety pin.
29. As required, attach the weight bucket or weight rod to the opposite end of the crane
by inserting the male flange into the female flange on the angle adjuster. Secure it
with the safety pin.
Tip: The angle adjuster has an integrated leveller. By turning it, the vertical plate on
the angle adjuster can be set to a perfect right angle. Correct setting of the angle
adjuster enhances the crane’s balance. Level the weight bucket before loading any
weights.
Before operation, all locking pins, locking screws etc should be inspected to ensure