Chart 1.1 - Clearance to Combustibles in Inches (see Figure 1.1)

Certain applications (awnings, fabrics, plastics, sprinklers,
insulation) may require the heater to be mounted at a
distance in excess of the published clearances to
combustibles. Contact the factory.

Figure 1.1 - Clearance to Combustibles

Model No.

Mounting

Angle*

Sides

Back

Top

Below

End(s)

Front

1RVT7

34,000 [Natural Gas]

14

N/A

13

46

22

N/A

30°

N/A

8

17

46

22

46

1RVT8

34,000 [LP Gas]

14

N/A

13

46

22

N/A

30°

N/A

8

17

46

22

46

End

End

SIDE VIEW

Below

Side

Side

END VIEW

0° MOUNTING ANGLE

Top

(to ceiling)

Back

This side down

Below

Front

30˚

* Heaters mounted on an angle between 0° to 30° must maintain clearances posted for 0° or 30°; whichever is greater.

Important! If the heater is mounted beneath a non-
combustible surface an 8 in. minimum top clearance
must be maintained from the top of the heater to
prevent overheating the controls.