beautypg.com

Dayton patio heaters, Warning – Dayton 1RVT8 User Manual

Page 10

background image

Dayton Installation, Operation, Maintenance and Parts Manual

Dayton Patio Heaters

®

1RVT7 and 1RVT8

10

WARNING

!

Heater Mounting

Improper suspension of the infra-red
heater may result in collapse and persons
being crushed. Always suspend from a
permanent part of the building structure
that can support the total force and
weight of the heater.

Failure to maintain minimum clearance to
combustibles may result in fire and/or
explosion, property damage, serious
injury or death. Always maintain
minimum clearances and post signs or

provided tags (F/N: LL01) where needed. Signs should
state the hazards for the particular application and be
legible for the building occupants. Consult the factory or
a factory representative for additional information on
signage compliance.

The heater can be suspended with chains or rigid
threaded rod. Local codes, or conditions such as wind
drafts or other variables can cause movement of the
heater and may require rigid threaded rod. Avoid
excessive movement and/or vibration of the gas
connection by rigidly mounting the heater. The heater
mounting brackets can be used in place of rigid
threaded rods (see Figures 2.5 - 2.6). Consult all
applicable codes before installation.

The heater must be level from side to side and can be
set at an angle between 0° and 30° from horizontal.
The gas connection and power cord must be located on
the lower side (see Figure 2.4).

Level end to end

The gas connection and

power cord must located

towards the lower side

of the heater (towards

the floor).

Mounting bracket

30°

End

Figure 2.4 - Heater Orientation

End

This manual is related to the following products: