Dayton 3VG79A User Manual
Dayton portable forced air heater, 3vg79a
Operating Instructions & Parts Manual
3VG79A
Dayton Portable Forced
Air Heater
Description
Dayton Model 3VG79A is a 200,000 Btu/Hr heater. This heater uses only Kerosene
or No. 1 fuel oil for combustion and electricity to run the motor. It is primarily
intended for indoor and outdoor temporary heating of well-ventilated buildings
under construction, alteration, or repair. It may be used in agricultural, industrial,
and commercial environments.
®
Form 5S4068
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Unpacking
1. Remove all packing items supplied
with heater for shipment.
2. Remove all items from carton.
3. Check items for any shipping
damage. If heater is damaged,
promptly inform dealer where you
bought heater.
Figure 1 - Model 3VG79A
ARL LOGO
G 004
®
Amperage
Model
Electrical Input
(during normal run)
3VG79A
120 Volt/60 Hertz
4.5
ELECTRICAL SPECIFICATIONS
GENERAL SPECIFICATIONS
Output
Hot Air Output
Fuel Tank Capacity
Fuel Consumption
Model
Rating Btu
(CFM Approx)
Fuel
(U.S. Gallons)
(U.S. Gallons/Hr.)
Motor RPM
3VG79A
200,000
600
Kerosene or No. 1 fuel oil
13.5
1.4
3450
Air Pump
Heater Weight
Heater Weight
Spark Plug Gap
Model
Pressure (psi)
(Pounds - with fuel)
(Pounds - without fuel)
(Inches)
3VG79A
6
77
66
.110
Version B - For Reduction
G016.J
®
Printed in U.S.A.
03430
0899/294/VCPVP