Table 2: DEFINITIONS OF THE DP715 CONNECTORS

DC 6V

Power adapter connection.

NETWORK PORT
(RJ-45)

10/100Mbps RJ-45 port toconnect to the network.

RESET

Factory Reset button: Press for 7 seconds to reset factory default settings.

Table 3: BASIC DEFINITIONS OF THE DP715 LEDS PATTERN

LEDs

POWER LED

Indicates Power. Remains green when power is connected, and orange when handset is
connected for charging.

NETWORK

Indicates Access to the Network. Remains ON while there is Access to the Network

REGISTERED

Indicates if the SIP accounts are registered

CALL

Indicates status of active calls.

Table 4: ADVANCED DEFINITIONS OF THE DP715 LEDS PATTERN

Pattern
Number

Condition

LED

LED Behavior

LED-01

Device has normal power

POWER

GREEN ON

LED-02

Handset is placed on base with battery to charge

POWER

ORANGE ON

LED-03

Power Error: Power is removed from the device

POWER

OFF

LED-04

Power supply with improper voltage is plugged in

POWER

Blink ( 0.5s on/ 0.5s off )

LED-05

Device has normal LAN connection and has obtained an
IP address

NETWORK

ON

LED-06

Link Down
Note : This is the default state while the device is booting.

NETWORK

Blink (1s on/ 1s off).

LED-07

Link Up but DHCP error

NETWORK

Blink ( 0.25s on/ 0.25s

off )

LED-08

Link Up but PPPoE error

NETWORK

Blink ( 0.5s on/ 0.5s off )

LED-09

All configured SIP accounts are registered

REGISTERED

ON

LED-10

SIP accounts are in the process of registering

REGISTERED

Blink ( 1s on/ 1s off )

LED-11

Device is booting, application has not started.

REGISTERED

OFF

LED-12

No account is configured on DP715

REGISTERED

OFF

LED-13

Registration Error - ANY SIP account experiences
registration failure.

REGISTERED

Blink ( 0.5s on/ 0.5s off -

05s on/ 2s off )

LED-14

Call is active. Any DECT handset is in an active call with
an external line.

CALL

Blink ( 0.5s on/ 0.5s off )

LED-15

No active call.

CALL

OFF

LED-16

DECT Error

CALL

5 sequence of Blink

(0.25s on/0.25s off) + 3s

off

LED-17

VMWI

CALL

Blink (0.25s on/ 0.25s off -
0.25s on/ 0.25s off - 0.25s

on/ 0.75s off)

LED-18

Boot up

ALL

GREEN ON

LED-19

Factory reset

ALL

GREEN ( 0.25s on/0.25s

off – 0.25s on/0.75s off )

This manual is related to the following products: