beautypg.com

Troubleshooting tips, Fuse replacement, Care and cleaning – GAMMA 5800 Els STRINGING MACHINE 2 POINT SC MOUNTING (Issue 1 - June 2006) User Manual

Page 20: Self diagnostics

background image

19

TROUBLESHOOTING TIPS

FUSE REPLACEMENT

To change the fuse, remove the power cord and pull the fuse holder straight out. Remove
the old fuse from the holder and replace it with the supplied spare. Replace the fuse holder
into the machine and check for proper operation.

CARE and CLEANING

With time and use, the clamping surfaces of your machine may become oily or dirty and
result in string or clamp slippage while stringing. Periodic cleaning of the String Clamps,
String Clamp Base, and String Gripper is recommended using a cleaning solvent such as
isoproyl alcohol and a mild abrasive tool such as a toothbrush.

String tension too tight or too loose.

- Check tension using a tension

calibrator and adjust machine calibra-
tion if necessary

Electrical system does not function.

- Check power source.

- Check power cord connection.

- Check stringing machine fuse.

String clamp base slips on turntable.

- Adjust Clamp Base Locking Nut.

String slips in gripper.

- Clean gripper jaws.

- Make sure string is wrapped over top

jaw of gripper prior to inserting between
gripper jaws.

String slips in clamps.

- Adjust gap between jaws.

- Clean clamp jaws.

PROBLEM

SOLUTION

SELF DIAGNOSTICS

The electronics of the machine are designed to provide self diagnostic trouble shooting
information, if parts of the machine do not function normally. When this occurs, error
codes will appear on the display. When an error code appears, contact customer service
for advice. Descriptions of several error codes follows:

Code

Corrective Action

C01

• Check wiring to & from the return microswitch

C03

• Check wiring & microswitches at end and return

C04

• Check wiring & microswitch at end of pull