Performance specifications – GAI-Tronics IDR1000A DC Remote User and Installation Manual User Manual
Page 8

Foreword
IDR1000A DC Remote Desk Set User and Installation Manual
02/12 4
Performance Specifications
Color ..................................................................................................................................................... Black 
Physical size .................................................................................................... 7.6 W 
 8.9 L  4.7 H inches
Weight ................................................................................................................................................ 2.4 lbs. 
Temperature range .............................................................................................................. −35º C to +70º C 
Humidity ...................................................................................................... 95% at 50º C (non-condensing) 
Line impedance ................................................................................................................ 600 ohms nominal 
Power input .................................................................................................. 10.5–16 V dc; 1.0 A maximum 
Nominal input level ........................................................................................................................ −10 dBm 
Nominal output level ...................................................................................... Range –25 to 0 dBm, −10 dB 
 
Range –15 to +5 dBm into 560 ohms
Frequency response............................................................................................ +/−3 dB from 300–3000 Hz 
Hum and noise .................................................................................. Less than −45 dB below rated outputs 
Audio output to speakers ................................................. 1 watt minimum with level in compression range 
Audio distortion .............................................................................................................. Less than 3% THD 
Maximum number of remotes .................................................................................................................. Ten 
DC current defaults 
 F1 
................................................................................................................................................. 5.5 mA
F2
............................................................................................................................................... 12.5 mA
F3
............................................................................................................................................... −5.5 mA
F4
............................................................................................................................................. −12.5 mA
Monitor
(Programmable) ........................................................................................................... −2.5 mA
N
OTE
: Each button listed above can be programmed from −14 to +14 mA in 0.5 mA increments.
Safety ................................................................................................................... Class III SELV equipment 
 
Powered by UL-listed (E104603) and CSA certified (LR67888) ac adapter
Line Interface ................................................................................................................ FCC Part 68 Exempt 
 
(Category II Tariff #260 service for private/leased lie application)