Applications, Connections – GAI-Tronics 113118-116 Modular TVP Barrier Assembly User Manual
Page 2

Pub. 42004-740L2A
Model 13118-016 Modular TVP Barrier Assembly
Page 2 of 3
f:\standard ioms - current release\42004 instr. manuals\42004-740l2a.doc
04/13
Applications
The Model 13118-016 Transient Voltage Protection (TVP) Barrier Assembly is designed to prevent
energy induced on the Page/Party
®
system cable from damaging the Page/Party
®
Interface (PPI) printed
circuit board assembly (PCBA). This assembly also allows party lines 3, 4 and 5 of the local zone to
connect with stations in other zones on the selected party line.
Connections
Table 1. Modular Terminal Blocks (TB1 & TB2) Field Wiring
Pin No.
Function Remarks
1
Page Line – L1
The red/blue wire of the page pair contained within the Page/Party
®
cable is attached to this position of the terminal block.
2
Page Line – L2
The blue/red wire of the page pair contained within the Page/Party
®
cable is attached to this position of the terminal block.
3
Party Line 1 – L1
The red wire of the party line #1 pair contained within the Page/Party
®
cable is attached to this position of the terminal block.
4
Party Line 1 – L2
The tan/red wire of the party line #1 pair contained within the
Page/Party
®
cable is attached to this position of the terminal block.
5
Party Line 2 – L1
The purple wire of the party line #2 pair contained within the
Page/Party
®
cable is attached to this position of the terminal block.
6
Party Line 2 – L2
The tan/purple wire of the party line #2 pair contained within the
Page/Party
®
cable is attached to this position of the terminal block.
7
Party Line 3 – L1
The blue wire of the party line #3 pair contained within the Page/Party
®
cable is attached to this position of the terminal block.
8
Party Line 3 – L2
The tan/blue wire of the party line #3 pair contained within the
Page/Party
®
cable is attached to this position of the terminal block.
9
Party Line 4 – L1
The brown wire of the party line #4 pair contained within the
Page/Party
®
cable is attached to this position of the terminal block.
10
Party Line 4 – L2
The tan/brown wire of the party line #4 pair contained within the
Page/Party
®
cable is attached to this position of the terminal block.
11
Party Line 5 – L1
The yellow wire of the party line #5 pair contained within the
Page/Party
®
cable is attached to this position of the terminal block.
12
Party Line 5 – L2
The tan/yellow wire of the party line #5 pair contained within the
Page/Party
®
cable is attached to this position of the terminal block.
13
Page Line – L1
No field connection (for internal use only)
14
Page Line – L2
No field connection (for internal use only)
15 CLS+
The spare orange wire contained within the Page/Party
®
cable is
attached to this position of the terminal block when All-Call control is
referenced to ground at field stations.
16 CLS−
This terminal is used with CLS+ when dry contact All-Call control is
employed at field stations via a separate pair of wires.
17 EGND
Earth
ground
18 EGND
Earth
ground