Basic Programming

The following programming command can be entered from any touch-tone telephone. Acceptance of a
data transfer command is indicated via a return code transmitted as an audible DTMF tone.

Call Time-out

The call time-out feature, which is used to limit the duration of calls, can be set between one minute and
4.5 hours. The time limit is set by entering a number from 120 to 32400.

This number represents the number of half-second increments of duration. Entering 0 results in a call
time-out of 4.5 hours.

Enter *37<120~32400>#

to assign a time limit, or change an existing time limit.

*37

Data transfer command

<120~32400> Call duration (60–16,200 seconds, 0 = 4.5 hours) – See example below.

#

End of sequence indicator

Multiply the desired time limit, in minutes, by 120 to determine the call duration.
Example: For a call duration of 5 minutes:

5 minutes

 120 = 600

Therefore, enter the character string *37600#, and the telephone returns a DTMF check-digit.

Table 1. Basic Programming Commands


Command


Return


Description

Default
Setting

*37<120~32400># c Write Call Time-out (120–32400

 ½ sec, 0 disables) 10 min.

‘c’ in the above return fields is the success tone (DTMF check digit).