Conduit installation details – GAI-Tronics DHS-201 Digital Intercom Stations User Manual
Page 8

Pub. 42004-453C
M
ODEL
DHS/DHF
200
S
ERIES
D
IGITAL
I
NTERCOM
S
TATIONS
Page 6 of 25
f:\standard ioms - current release\42004 instr. manuals\42004-453c.doc
10/12
Conduit Installation Details
GAI-Tronics recommends installing wiring in conduit to protect against accidental damage and
vandalism. To prevent moisture from entering the enclosure, we strongly recommend the following:
Conduit should enter the enclosure from the bottom.
If entered from the top, the conduit must be internally sealed to prevent moisture ingress.
Sealed fittings should be installed at all cable entry points.
Silicone sealant or equivalent should be applied around and inside all conduit entries.
Figure 6. Bottom entry conduit installation details
for metallic enclosures
Figure 7. Top entry conduit installation details for
metallic enclosures (NOT recommended)
- DHF-201GN Digital Intercom Stations DHF-201HS Digital Intercom Stations DHF-201 Digital Intercom Stations DHS-201HS Digital Intercom Stations DHF-202 Digital Intercom Stations DHF-202GN Digital Intercom Stations DHF-203 Digital Intercom Stations DHF-201HSGN Digital Intercom Stations DHF-202HS Digital Intercom Stations DHF-202HSGN Digital Intercom Stations DHF-204 Digital Intercom Stations