beautypg.com

Power connection, Mounting instructions, Connection instructions – GAI-Tronics GC-AC1 EZ Page Industrial Intercom User Manual

Page 4: System line balance

background image

Pub. 42004-307G

EZ

P

AGE

I

NDUSTRIAL

I

NTERCOMS

Page 4 of 16

f:\standard ioms - current release\42004 instr. manuals\42004-307g.doc
03/15

Power Connection

WARNING

 Installation techniques must comply with all applicable electrical safety hazards/electrical codes.
 Remove local power before opening the unit or before performing any service.

Input
Voltage


Model


Conductor 1


Conductor 2


Conductor 3


Conductor 4

120 V ac via
supplied 9.5-foot
cord w/NEMA
5-15P plug

GC-AC1 Hot

Black Neutral White Safety

ground

Green N/A --

12–16 V dc
(See note)

GC-DC1 (+)

Red

(−) Black

Safety

ground

Green Not

used
(cut off)

White

230 V ac
(See note)

GC-AC2 Hot

Red

Neutral
(non-
US)

White Safety

ground

Green Not

used
(cut off)

Black

N

OTES

:

1. For Model GC-DC1 (12–16 V dc), the integral power cable is designed for connection to Class 2

circuits. For Model GC-AC2 (230 V ac) termination of the integral primary power cable must be
made using a UL-approved junction box. If a customer-supplied interconnect plug is desired for
interconnect, the plug must be UL-approved and rated for such purposes.

2. The audio/control wiring for all models is designed for connection to Class 2 circuits.

Mounting Instructions

The wall’s mounting surface composition and hardware to be used (customer-supplied) must be suitable
to withstand the unit’s weight to prevent damage and/or personal injury.

If the unit is mounted to building structure, GTC Part No. 12704-001 Mounting Bracket Kit should be
used. Refer to Pub. 42003-134 that accompanies the kit for more information.

There are two 0.406-inch (10.4 mm) diameter holes located in the mounting flanges spaced 5.875 inches
(149.3 mm) apart. See Figure 1. The suggested mounting height for all station enclosures is 54 inches
(137 cm) from the floor to the centerline of the enclosure.

Connection Instructions

System Line Balance

Each system requires termination of the audio pair wires with the 1 k/1-watt resistor assembly included
with each unit. The line balance resistor assembly is made for easy installation into the customer-
supplied junction box. Only one line balance resistor assembly is needed per system.

For cable runs that are approximately 0.75 mile (1.2 km) or longer, it is recommended that the resistor
assembly be installed in a junction box that is close to the center of the system.