GAI-Tronics 476-002 Centra-Page Flush-Mount Station User Manual
Page 2

Pub. 42004-216B
Model 476-002 Centra-Page Flush-Mount Station
Page:
2 of 7
\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-216b.doc
08/05
The Model 476-002 Station, like other Centra-Page stations, operates in conjunction with a plug-in Line
Card PCBA housed in the central cabinet card rack assembly. The line cards are sold separately. The card
contains the handset dc power source, dual-switching relays, and a 16-watt speaker amplifier with 8-ohm
and 70-volt line outputs.
If installing this station as an add-on, please consult the following chart to ensure proper power is supplied.
Power Supply Current Requirements in Amps
Mode
10 Cards
20 Cards
30 Cards
Standby 0.8
1.5
2.3
Page (Full load)
5.7
11.4
17.1
Alarm (Typical)
3.8
7.5
11.3
Alarm (Max. Level)
12.5
25.0
37.5
N
OTES
:
1. Ratings at 27.0 V dc at central cabinet. Add 8% for page and alarm at 28.8 V dc.
2. Full load is defined as 15-watt load on all cards with levels as adjusted at factory; 2-watt alarm output.
3. Typical load is defined as 7.5-watt load (such as 16-ohm loudspeaker connected to 8-ohm output).
4. Maximum level is defined as 15-watt loads and level control adjusted for 15-watt alarm level on all
cards.
5. Ratings for alarm based on continuous tones. Pulse tone reduces current to about 60%.