Gas connection (Fig. 10)

Connect the appliance to the gas cylinder or to the installation according to the prescribed
standards in force, and ensure beforehand, that the appliance matches the type of gas
available. Other wise, see ”Adaptation to various types of gas”. Further more, check that the
feed pressure fall swithin the values described on the table: ”User chacteristics”.

Fig. 11

Rigid/semi rigid metalconnection

Carry out the connection with fittings and metal pipes (even flexible pipes) so as to obtain
counter stress the inner parts of the appliance.
N.B. - when the installation has been carried out, check the perfect sealing of the entire
connection system, by using a soapy solution.

Adaptation to varius types of gas (Fig. 11)

Should the appliance be pre-set for a different type of gas than available, procreed as
follows:

• replace the injector (Fig. 13) with the corresponding type of gas to be used (see table

“User characteristics“);

• to adjust to the minimum, use a screwdriver on the screw placed on the tap (Fig. 13) after

turning the tap to its minimum position. For GPL (butane/propane) screw tight.

A

B