beautypg.com

Fronius Selectiva 8 kW User Manual

Page 46

background image

44

Selectiva 16 kW

Selectiva 4060

12.5 A

4600 W

48 V

60 A

Selectiva 4075

15 A

5700 W

48 V

75 A

Selectiva 4090

11 A

6800 W

48 V

90 A

Selectiva 4120

14 A

8800 W

48 V

120 A

Selectiva 4140

15 A

9500 W

48 V

140 A

Selectiva 4160

15.5 A

9600 W

48 V

160 A

Selectiva 8040

8.5 A

5000 W

80 V

40 A

Selectiva 8060

12 A

7500 W

80 V

60 A

Selectiva 8075

14.5 A

9100 W

80 V

75 A

Selectiva 8090

14.5 A

9200 W

80 V

90 A

Device-specific data
Device

Max. AC cur-
rent

Max. AC power Charging volt-

age

Charging cur-
rent

WARNING! An electric shock due to a fault current can be fatal. Nothing other
than a type B residual current circuit breaker should ever be used for connecting
the device to the mains.

Mains voltage (-10% / +15%) *
Optional:

3~ NPE 400 / 230 V / 50/60 Hz
3~ PE 400 / 230 V / 50/60 Hz

Mains fuse protection **

32 A

Minimum mains cable cross section
Selectiva 8120 / 8140
Selectiva 8160 / 8180

4 mm² (0.0062 in²)
6 mm² (0.0093 in²)

Duty cycle

100%

EMC device class

B

Protection class

Protection class 1

Degree of protection ***

IP 20

Overvoltage category

III

Operating temperature ****

-20 °C to +40 °C
(-4 °F to 104 °F)

Storage temperature

-25 °C to +80 °C
(-13 °F to 176 °F)

Relative humidity

maximum 85%

Maximum altitude above sea level

2000 m (6561 ft.)

Mark of conformity

according to rating plate

Product standard

EN62477-1

Dimensions l x w x h

647 x 247 x 392 mm
(25.47 x 9.72 x 15.43 in.)

Weight (with standard mains cable and charger
lead)

34 kg (74.96 lb.)

Pollution level

3

*)

The device is approved for operation on neutral-earthed mains networks with a
maximum outer conductor nominal voltage of 400 V.

**)

The earth leakage current is less than 3.5 mA.

***) For indoor use only, do not expose to rain or snow
****) A high ambient temperature may result in a power reduction (derating)

This manual is related to the following products: