27
EN
-
Error overtemperature ON/OFF:
-
ON ... Error message in the event of battery overtemperature
Charging process stops and can only be continued once the battery has cooled
down and been reconnected
-
OFF ... No error message in the event of battery overtemperature
-
Warning overtemperature ON/OFF:
-
ON ... Warning in the event of battery overtemperature
-
OFF ... No battery overtemperature warning
Equalize charge:
-
ON:
If the battery remains connected to the battery charging system for the duration of the
"equalize charge delay", then a special type of charging takes place. This prevents
acid stratification.
-
OFF:
There is no equalising charge.
Delay:
Charge start delay:
Delay time (minutes) of actual start of charging relative to the moment when charge start
was initiated
Charge end delay:
Delay time (minutes) before charge end is signalled (e.g. green indicator) relative to the
moment when charging actually stopped
At mains failure restart charging:
If this option is chosen, the charging process is restarted automatically as soon as the
mains supply becomes available again after a disruption to the electrical mains supply.
Calendar:
The calendar function allows charging to be started automatically according to the follow-
ing criteria:
-
Time window in which charging may not be started if a battery is connected
-
Time window in which charging is to be started using a defined characteristic 1 if a bat-
tery is connected
-
Time window in which charging is to be started using a defined characteristic 2 if a bat-
tery is connected
To activate the calendar function,
select the setting "ON" and confirm
Definition of characteristic 1:
-
Type of battery
e.g. Pb-Wet
-
Characteristic:
e.g. RI
-
Additional settings, depending on the
characteristic:
e.g. Charging time 7-8 h
1